This intelligent controller, adopting function block programming, having large programming capacity, being f reely |
|
fprogrammed according to different users and different fields, can run at your desired time table and the RTC |
|
accuracy can reach second and makes your time control more accurate. And up to 128 time sessions can |
|
be set , especially suitable for time-control system. |
|
Safety password function makes your program absolutely safe. Before writing program, password can be set. And only |
|
after entering the correct password, can the program be modified. |
|
It is equipped with a removable, convenient and programmable LCD, providing 64 friendly human-machine interfaces, |
|
32 virtual keys, having the function to display the alarming message and parameter and to modify the parameter. |
|
When needed, it can be installed. And when not needed, it can be removed and replaced with an ordinary front panel. |
|
Thus the cost will be greatly reduced. |
|
The input can receive not only the digital input but also the analogue input to perform the control and . transmission of |
|
fthe temperature, moisture, pressure, flow level unit and so on. |
|
It has well-featured and compact design with 8 point input and 4 point output. Equipped with expansion module, it can |
|
be expanded into 82 I/O better ,and to MAX 122I/O.It can be connected with telephone voice module and remote control |
|
module to perform the notification and alarming function. And the connection between the host and the module can |
|
be Bridge SR-CBA or flexible connection SR-ECBA. |
|
The machine has short-circuit protection (internal) and relay output protection (external) function, which makes your |
|
usage safer and easier. |
|
|
|
|
Power supply |
Power
|
DC12V-24V
|
Input parameters: |
Input No
|
8(A0-A5,B4-B5)
|
Digital input
|
8(A0-A5,B4-B5)
|
Analogue input
|
6(A0-A5)
|
Power range
|
DC0-24V(digital)/DC0-10V(analogue)
|
Input signal0
|
DC0-5V
|
Input signal1
|
DC10-24V
|
Output parameters: |
Output No
|
4(QA0-QA3)
|
Output type
|
Relay output
|
Output voltage
|
DC0-24V
|
Output current
|
Resistive load 10A/Inductive load 2A
|
Environment temperature: |
Running temperature
|
0ºC~55ºC
|
Storage/shipment
|
-40ºC~70ºC
|
Switch frequency: |
Mechanism
|
10Hz
|
Resistor/light load
|
2Hz
|
Sensitive load
|
0.5Hz
|
Other parameters: |
Clock buffer memory at 25ºC
|
80h
|
RTC accuracy
|
Max±5s/day
|
Protection |
IP20
|
Emission on line
|
EN55011(B)
|
The main frequency range
|
47-63Hz
|
Function block No
|
128
|
Program storage capacity
|
64K
|
Isolation intensity
|
IEC1131
|
|
|
|
|