Task: | Program |
---|---|
Structure: | Combination |
Mathematical Model: | Linear |
Still deciding? Get samples of US$ 49/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
|
This model is an AC power supply, with digital input, 6 points AC input, 4 points relay output | |||
|
Exquisite and compact design | |||
|
Multi-functional, easy operating, convenient, easy learning | |||
|
Operation temperature: :-20ºC-70ºC |
|
Timers :127 | |
|
Storage/Transportation -40ºC-70ºC |
|
Counters :127 | |
|
Protection:IP20 |
|
Function blocks : 127 | |
|
Interference Regulation: EN55011(B Class) |
|
RTC time intervals:127 |
|
|
RTC accuracy: MAX ±5S/day |
|
Storage capacity:64K |
|
|
Certificate:CE |
|
Insulation Intensity: IEC1131 |
|
|
Installation: Use a standard DIN rail or screw for installation |
|
Dimensions:90*71*58(Unit:mm) |
|
|
Power supply | |||
Rated voltage:AC100-240V |
Main voltage operation range:AC85-265V | |||
AC220V consumption: 3W |
Allowable main frequency:47-63Hz |
|||
|
Digital input | |||
|
Signal 0:AC 0-40V | Input current:<0.1mA | ||
|
Signal 1:AC 80-240V | Input current:<0.2mA | ||
|
Digital output | |||
Output type: Relay output | Wiring insulation: Yes | |||
Points per set:1 | Continuous current max value:MAX 10A | |||
|
Switch frequency | |||
Mechanism: 10Hz | Resistor load: 2Hz Inductive load: 0 |
FAB Intelligent Controller Series is a new programmable controller launched by ARRAY, with the programming by FBD (Function Block Diagram) , which is simpler and easier to learn than the conventional PLC (ladder diagram and instruction). In the design concept of ARRAY FAB series products, traditional separated controller of PLC is combined with the writer on which the program can be written directly by using the function keys on the LCD front panel in order to reduce the cost and bring convenience to users. ARRAY FAB is very compact and light-weighted, especially suitable for internal installation usage.
In addition, FAB intelligent controller series can perform the local and remote Internet communication and monitoring. And FAB can be used with voice module to perform telephone remote control, voice prompting, auto-dialing and other functions. At present, the ARRAY FAB is widely used in various areas such as industry, agriculture and automatic house control. It can be used almost everywhere
FAB2 Series PLC Features: Password protection Add power indicator Improve analog accuracy Improve RTC accuracy Improve PLC running speed 2 channels with 485 interface and 1 channel with the programing interface Support ARRAY Text Panel(SH300) Support the standard Modbus RTU protocol(only read) Technical Parameters Item AF-10MR-A2 AF-10MR-D2 AF-10MR-E2 AF-10MT-D2 AF-10MT-GD2 AF-10MT-E2 AF-20MR-A2 AF-20MR-D2 AF-20MR-E2 AF-20MT-D2 AF-20MT-GD2 AF-20MT-E2 Surge Immunity 2kv(common mode), 1kv(differential mode), Level 3 (IEC61000-4-5) Electrostatic Discharge (outer casing) ±8kv(air discharge)/±6kv(contact discharge), Level 3 (IEC61000-4-5) Ambient Temperature -10ºC~+55ºC Storage Temperature -40ºC~+70ºC Ambient Humidity 5%~95%RH Degree of Protection IP20(Non-waterproof) Installation Fixing with M3 screws or Standard DIN rail mounting Dimensions (mm) 71.6*90.4*51.3(10 points);126.4*90.4*51.3(20 points) Programming Language FBD Points 10 points/20 points Memory Capacity 127 FBDs Real-time Clock 160h Password Protection yes Analog Operation At most 12 channels with DC 0-10V voltage Simulate Monitoring Yes Communication Interface support 2 channel with RS485 and 1 channel with program interfaces Baud Rate 9600bps/19200bps Communication Protocol Self-defined protocol/MODBUS RTU protocol (only read) Power Supply Rated Voltage AC100-240V DC12-24V AC/DC12-24V DC12-24V DC12-24V DC12-24V Permissible Range DC85-260V DC10-28V AC/DC10-28V DC10-28V DC10-28V DC10-28V Power Consumption <10w <7w <7w <2w <2w <2w Digital Input Input Type NPN/PNP NPN/PNP NPN/PNP NPN/PNP NPN/PNP NPN/PNP Input Signal 0 AC0-40V DC0-5V AC/DC0-5V DC0-5V DC0-5V DC0-5V Input Signal 1 AC80-240V DC10-24V AC/DC10-24V DC10-24V DC10-24V DC10-24V Isolation Photoelectric isolation -- -- -- -- -- Isolated Group 6/12 groups Isolated Voltage 2500/5000Vr.m.s Digital Output Output Type Relay Relay Relay Transistor(NPN) Transistor(PNP) Transistor(NPN) Isolation Method Relay isolation Relay isolation Relay isolation - - - Analog Input Input Type -- (DC0-10V)/6 inputs -- (DC0-10V)/6 inputs (4-20mA)/2 inputs -- (DC0-10V)/12 inputs (DC0-10V)/12 inputs (DC0-10V)/12 inputs Type AF-10MR-A2 AC100V-240V 6 points digital input 4 points relay output AF-10MR-D2 DC12V-24V 6 points digital input (can be used as analog inputs) 4 points relay output AF-10MR-E2 AC/DC12V-24V 6 points digital input 4 points relay output AF-10MT-D2 DC12V-24V 6 points digital input (can be used as analog inputs) 4 points NPN transistor output AF-10MT-GD2 DC12V-24V 6 points digital input (can be used as analog inputs) 4 points PNP transistor output AF-10MT-E2 DC12V-24V 6 points digital input 4 points NPN transistor output AF-20MR-A2 AC100V-240V 12 points digital input 8 points relay output AF-20MR-D2 DC12V-24V 12 points digital input (can be used as analog inputs) 8 points relay output AF-20MR-E2 AC/DC12V-24V 12 points digital input 8 points relay output AF-20MT-D2 DC12V-24V 12 points digital input (can be used as analog inputs) 8 points NPN transistor output AF-20MT-GD2 DC12V-24V 12 points digital input (can be used as analog inputs) 8 points PNP transistor output AF-20MT-E2 DC12V-24V 12 points digital input 8 points NPN transistor output Auxiliary Module AF-2322 the cable is used to read/write the program by PC 232 port AF-DUSB2 the cable is used to read/write the program by PC USB port AF-HMI The removable LCD panel Dimensions Take the 10 points module as an example. The 20 points modules share the same width and height, the only one difference exists in the length. Type Dimensions(mm) 10 points main module 71.6*90.4*51.3 20 points main module 126.4*90.4*51.3